General (UPS-HB power frequency online HB series UPS) |
UPS-HB series runs in online sine wave made with isolating output transformer, input under - voltage, over - voltage protection , output under-voltage,over -voltage, over load, short circuit protection. It features high stability , noise filtering and strong over loading. The specially designed static change - over switch makes the zero transition offers real Uninterrupted power supply. The computer monitoring is optional. |
Performanch parameter (UPS-HB power frequency online HB series UPS) |
¡¡lnput voltage |
220V¡À 25% |
¡¡lnput frequency |
50Hz/60Hz¡À 5% |
¡¡Control mode |
SPWM |
¡¡Output waveform |
Sine wave, THD <3% |
¡¡Output voltage accuracy |
220V¡À 1.5% |
¡¡Output frequency |
50Hz/60Hz¡À 0.5% |
¡¡Output transient response |
¡À4% (100% load varies) |
¡¡Output wave crest ratio |
3: 1 |
¡¡Output overload capacity |
120% rated load, turn to bypass within 25s,120%25s |
¡¡Output power factor |
0.8 |
¡¡Transition time when power is ¡¡off |
Zero |
¡¡Battery type |
Maintenance-free lead acid battery, 16 12VDC |
¡¡Time for supplying power |
10 min (Standard), the time can be selected if the machine is a long time delay machine |
¡¡Charge time |
Charge 90% within 7~10h |
¡¡Protection function |
Protection against overload, short-circuit, battery under voltage |
¡¡lndication Status |
Normal commercial power (Green lamp) , normal inversion (Green lamp), bypass (Yellow lamp), short-circuit or under voltage (Red lamp) |
¡¡Sound alarm |
When commercial power is off or too low, it will sound for once every 4s; when the battery is under voltage, it will sound for once every 1s; when the fault shows or battery is used up, it will sound continuously. |
¡¡lnterface to computer |
9-pin D type connector (Optional part) |
¡¡Environment |
Temperature: 0~40 , relative humidity: 95%(no condensation) | |
SPEC & MODLE (UPS-HB power frequency online HB series UPS) |
Model |
Outline size(cm) |
NW(kg) |
Model |
Outline size(cm) |
NW(kg) |
1-inletand 1-outlet |
1KVA |
55¡Á 27¡Á 70 |
42 |
3-inlet and 3-outlet |
10KVA |
76¡Á 55¡Á 104 |
190 |
2KVA |
55¡Á 27¡Á 70 |
60 |
10KVA |
76¡Á 55 ¡Á104 |
195 |
3KVA |
67¡Á 27¡Á 72 |
70 |
15KVA |
76¡Á 55¡Á 104 |
228 |
5KVA |
67¡Á 27¡Á 72 |
95 |
15KVA |
76¡Á 55¡Á 104 |
228 |
6KVA |
67¡Á 27¡Á 72 |
100 |
20KVA |
72¡Á 56¡Á 116 |
281 |
10KVA |
60¡Á 31¡Á 87 |
120 |
20KVA |
78¡Á 58¡Á 115 |
350 |
15KVA |
45¡Á 55¡Á 95 |
203 |
30KVA |
72¡Á 56¡Á 116 |
317 |
20KVA |
72¡Á 56¡Á 116 |
256 |
30KVA |
78¡Á 58¡Á 115 |
420 | |
|