¡¡ Home       About us        Products        Certificate       Feed back       Contact us
¡¡ ¡¡ ¡¡
¡¡
¡¡
Electrical Items >> UPS and Stabilizer >> HBR1 soft starter ¡¡

 General (HBR1 series motor power supply) motor soft starter
       The  soft  starting  technology of AC squirrel-cage motor has been applied for many years in the developed country, it has successfully solved the following problems during AC motor starting: supply  voltage  quality  affected  by  large  starting
current,  high  power  consumption  of  power supply circuit, impact on mechanical equipment. HBR1 series full digital soft starter adopts advanced 16
digits single-chip microcomputer as the core to controlthyristor of high power, it has obvious functions like soft starting, current-limit starting, full voltage
starting, double-ramp starting, soft starting and so on, besides, it has  over  current protection, overload protection,  phase failure protection,etc, its all parameterscan  be  set  automatically  according to loads .  Its  output  voltage  rises as  per setting regulation, to make the controlled motor get full voltage from setting £¦#118alue. After the starter finishes starting, it will bypass the thyristor,
and let AC contactor begin to work. HBR1 series soft starter covering 5.5~500kw, is widely applied to various fields like metallurgy,  petrol,  chemical
industry, construction, cement, mining, environmental protection and so on, it is the best new generation productinstead of star delta starter, reactor starter and auto step-down starter.
 Features (HBR1 series motor power supply)
¡ñ With 16-digit single-chip microcomputer, full digital automatic control.
¡ñ  Starting torque, current, voltage and time can be set flexibly according to different loads.
¡ñ  Provide motor with smooth and gradual starting course, reduce the impact on power grid from starting current
¡ñ  The starting current can be adjusted according to loads.
¡ñ  The character of soft stopping is helpful for prolonging the life of electric contact and satisfying the machinery
    requirements on different occasions.
¡ñ  With over current protection, overload protection,phase failure protection and so on, it can preventthe motor and equipment being damaged effectively.
¡ñ  External control interface provided is convenient foruser to realize interlocking or self-control.
¡ñ  Delay the input of starting control and soft stoppingcontrol. Starting delay relay outputs, fault relay outputs.
¡ñ  Stop and operate soft stopping freely, the time of soft stopping is adjustable.
¡ñ  Novel product structure, small volume, reliable performance, convenience for installation and operation.
¡ñ The isolation of double power supply is good forprotecting control part against interference of kinds of strong electricity.
 Pump  (HBR1 series motor power supply)

      No water pressure fluctuation in the pipe: the soft starter can solve the problem that there is some fluctuation of
water  pressure in  the pipe  when  water pump motor starts or stops, its starting current can be down to 1/3~1/4
time. Besides, the current peak £¦#118alue can be eliminated during star delta starting.

 Fan  (HBR1 series motor power supply)

     The belt can't skid: soft starter can prevent the belt skidding and can reduce the stress of bearing when the fan
starts.

 Air compressor,centerifuge,agitator (HBR1 series motor power supply)

      Air compressor, centrifuge, agitator
For reducing stress of machines: the soft starter can reduce the stress on gear box and driving belt when
compressor, centrifuge and agitator starts.

 Conveying belt (HBR1 series motor power supply)

Conveying belt
The soft starter can take effect on preventing product falling down or being damaged when the conveying belt
starts  or stops, and it also can reduce the belt abrasion and stress on the gear box for skidding of belt when
starting, its hydraulic coupling can take the place of direct coupling.

 Common performanch (HBR1 series motor power supply)

Common performance
For reducing starting current: over high starting current will result in the falling of power grid voltage, subsequently,
it causes the interference to the load of weak power grid. Soft starter can solve above problem, the area of cable
and the size of fuse will get small correspondingly, so the installation cost can be reduced. Reduce starting current
can be good for reducing electricity expense. 
 Description about control terminal (HBR1 series motor power supply)
Terminal mark terminal name Descrition
CM Contact input common terminal Common terminal of contact input signal
RUN Starting input terminal Motor begins running when RUN-CM switches on
STOP Stopping input terminal Motor begins stopping when STOP-CM breaks
OE1,2,3 External fault input terminal Motor stops immediately when OE-CM breaks
JRA¡¢B¡¢C Running output signal JRA-JRB is the NO contact,JRB-JRC is the NC contact
JMA¡¢B¡¢C Alarming output signal JMA-JMB is the NO contact,JMB-JMC is the NC contact
 General data (HBR1 series motor power supply)

¡ñ Time of stopping falling: 0~60S
¡ñ Limit of starting current: 50~400%
¡ñ Time of starting to rise: 0~100s
¡ñ Overload current: 50~300%
¡ñ Rated power supply: three-phase 380V
¡ñ General motor:7.5~500KW
¡ñ Environment temp.: -10¡æ~55¡æ
¡ñ Initial voltage: 40-380V
¡ñ Initial time: 0~20S 

Spec.&model Power(KW) Over size(mm) Installation size (mm) Weight(kg)
A B C D E F
HBR1-S-17KW 17 328 234 224 288 305 184 17
HBR1-S-22KW 22 328 234 224 288 305 184 17
HBR1-S-30KW 30 328 234 224 288 305 184 17
HBR1-S-37KW 37 410 278 223 370 390 150 17
HBR1-S-45KW 45 410 278 223 370 390 150 17
HBR1-S-55KW 55 410 278 223 370 390 150 17
HBR1-S-90KW 90 1957 670 580 1900 460 570 110
HBR1-S-115KW 115 1957 670 580 1900 460 570 110
HBR1-S-130KW 132 1957 670 580 1900 460 570 110
HBR1-S-160KW 160 1957 670 580 1900 460 570 110
HBR1-S-200KW 200 1957 670 580 1900 460 570 110
HBR1-S-250KW 250 1960 800 660 1900 550 645 150
HBR1-S-320KW 320 1960 800 660 1900 550 645 150
HBR1-S-400KW 400 2260 1100 800 2200 800 700 200
HBR1-S-500KW 500 2260 1100 800 2200 800 700 200

 

 

 

 

 

 

 

 

pec.&model Power(KW) Over size(mm) Installation size (mm) Weight(kg)
A B C D E F
HBR1-Z-17KW 17 255 286 215 253 305 256 8
HBR1-Z-22KW 22 255 286 215 253 305 256 8
HBR1-Z-30KW 30 255 286 215 253 305 256 8
HBR1-Z-37KW 37 330 390 235 330 300 360 14.5
HBR1-Z-45KW 45 330 390 235 330 300 360 14.5
HBR1-Z-55KW 55 330 390 235 330 300 360 14.5
HBR1-Z-90KW 90 540 430 250 480 510 385 37
HBR1-Z-115KW 115 540 430 250 480 510 385 37
HBR1-Z-130KW 132 1957 670 560 1900 460 570 37
HBR1-Z-160KW 160 1957 670 560 1900 460 570 37
HBR1-Z-200KW 200 1957 670 560 1900 460 570 37
HBR1-Z-250KW 250 1957 670 560 1900 460 570 37
HBR1-Z-320KW 320 1957 670 560 1900 460 570 37
HBR1-Z-400KW 400 1957 670 560 1900 460 570 37
HBR1-Z-500KW 500 1957 670 560 1900 460 570 37

hits£º1256    addtime£º2009-09-19 £Ûback£Ý

¡¡
¡¡
¡¡
¡¡
¡¡